Don't take our word for it. Read the lab's.

Independent laboratory test reports, published whole. Start with the latest lot — August 2026, the chemical and physical halves of NBML report 1070, covering IS 3812 Part 1 and Part 2 between them. Previously tested lots follow, kept separate so no specification is assembled out of the best figure from each.

At a glance

What the reports actually say.

The numbers buyers check first, each shown with the report number and date it came from. Latest test result on the left of every pair, applicable requirement on the right — the two are never the same claim.

93.08% SiO₂ + Al₂O₃ + Fe₂O₃ requirement ≥ 70%NBML-CHEM-NN-1070-2026 · 04 Aug 2026
0.74% Loss on ignition requirement ≤ 5%NBML-CHEM-NN-1070-2026 · 04 Aug 2026
382 m²/kg Fineness, Blaine requirement ≥ 320NBML-NN-1070-2026 · 04 Aug 2026
0.09% Soundness, autoclave requirement ≤ 0.8%NBML-NN-1070-2026 · 04 Aug 2026

Latest lot — August 2026 NBML-CHEM-NN-1070-2026 & NBML-NN-1070-2026 · issued 04 Aug 2026

Parameter Latest test result Applicable requirement Report
SiO₂ + Al₂O₃ + Fe₂O₃93.08%≥ 70% IS 3812 P1NBML-CHEM-107004 Aug 2026
Silica (SiO₂)51.08%≥ 35% IS 3812 P1NBML-CHEM-107004 Aug 2026
Loss on ignition0.74%≤ 5.0% IS 3812 P1NBML-CHEM-107004 Aug 2026
Sulphur trioxide (SO₃)1.83%≤ 3.0% IS 3812 P1NBML-CHEM-107004 Aug 2026
Magnesium oxide (MgO)1.22%≤ 5.0% IS 3812 P1NBML-CHEM-107004 Aug 2026
Available alkalis0.98%≤ 1.5% IS 3812 P1NBML-CHEM-107004 Aug 2026
Fineness — Blaine air permeability382 m²/kg≥ 320 m²/kg IS 3812NBML-NN-107004 Aug 2026
Retained on 45 µm sieve30.12%≤ 34% IS 3812NBML-NN-107004 Aug 2026
Soundness — autoclave expansion0.09%≤ 0.8% IS 3812NBML-NN-107004 Aug 2026
Lime reactivityAwaited≥ 4.5 N/mm² IS 3812NBML-NN-1070under test
Compressive strength — 28 day, % of controlAwaited≥ 80% IS 3812NBML-NN-1070under test

Latest tested results available — remaining tests pending. Lime reactivity and 28-day compressive strength were still under test when NBML-NN-1070-2026 was issued. Until those figures are released this lot is not presented as a completed pass against IS 3812; we send them with the lot certificate on request.

Previous tested lots Earlier samples and an independent cross-check — history, not the current specification

Parameter Test result Applicable requirement Report
SiO₂ + Al₂O₃ + Fe₂O₃94.72%≥ 50% ASTM C618SGS CG26-014360.00113 Jul 2026
Loss on ignition0.34%≤ 6.0% ASTM C618SGS CG26-014360.00113 Jul 2026
Sulphur trioxide (SO₃)0.061%≤ 5.0% ASTM C618SGS CG26-014360.00113 Jul 2026
Moisture content0.04%≤ 3.0% ASTM C618SGS CG26-014360.00113 Jul 2026
Retained on 45 µm sieve — silo C1020.40%≤ 34% IS 3812NBML-NN-0978-0113 Jul 2026
Retained on 45 µm sieve — silo C0421.00%≤ 34% IS 3812NBML-NN-0978-0213 Jul 2026

Each row is reproduced verbatim from the signed report named beside it, and belongs to that sample alone — these are separate lots and separate samples, and no specification should be assembled by taking the best figure from each. Requirement columns follow IS 3812 (Part 1):2013 for use as pozzolana and (Part 2):2013 for use as admixture. The SGS rows are a partial chemistry cross-check against ASTM C311 methods on a separately supplied, unclassified sample — full ASTM C618 Class F qualification is still in progress and is not claimed here.

The documents

Independent laboratory test reports, in full.

The latest lot leads — chemistry to IS 3812 Part 1, physicals to Part 1 & Part 2, both from the same August 2026 lot. Previously tested lots follow below. Click any report to open the original PDF exactly as the laboratory issued it — letterhead, QR verification code, stamp and authorised signature intact. These are test reports on the samples named in them, not a certification of the product.

Latest lot — August 2026

Both halves of NBML report 1070 — the full chemical analysis and the physical results, drawn from the same lot on the same date, 04 Aug 2026. Between them they cover the requirements of IS 3812 Part 1 and Part 2, except lime reactivity and 28-day compressive strength, which were still under test when the report was issued.

Latest lot · chemical First page of the NBML chemical analysis test report, number NBML-CHEM-NN-1070-2026 Open PDF
NBML Building Materials Testing Lab IS 3812 (P1)

Fly ash — full chemical analysis

Report no.
NBML-CHEM-NN-1070-2026
Issued
04 Aug 2026
Tested
29 Jul – 03 Aug 2026
Method
IS 1727 · IS 3812
  • SiO₂+Al₂O₃+Fe₂O₃93.08%min 70
  • Silica (SiO₂)51.08%min 35
  • Alumina (Al₂O₃)24.15%
  • Magnesium oxide1.22%max 5.0
  • SO₃1.83%max 3.0
  • Loss on ignition0.74%max 5.0
  • Available alkalis0.98%max 1.5
Latest lot · physical First page of the NBML physical test report, number NBML-NN-1070-2026 Open PDF
NBML Building Materials Testing Lab IS 3812 P1 & P2

Fly ash — physical test results

Report no.
NBML-NN-1070-2026
Issued
04 Aug 2026
Source
NTPC Ltd (Odisha)
Method
ASTM C204 · C311
  • Fineness, Blaine382 m²/kgmin 320
  • Soundness, autoclave0.09%max 0.8
  • Retained on 45 µm30.12%max 34

Latest tested results available — remaining tests pending. Lime reactivity and 28-day compressive strength were still under test when this report was issued, so this lot is not presented as a completed pass against IS 3812. The completed figures are shared with the lot certificate on request.

Previous tested lots July 2026 — an SGS chemistry cross-check to ASTM C311 methods, plus fineness on the C10 and C04 silo lots. Separate samples from the August lot above. 3 reports
First page of the SGS India test report for dry fly ash, report number CG26-014360.001 Open PDF
SGS India Pvt Ltd ASTM C618

Dry fly ash — chemical & fineness analysis

Report no.
CG26-014360.001
Issued
13 Jul 2026
Sample
Dry fly ash (DFA), ~2 kg
Method
ASTM C311
  • SiO₂+Al₂O₃+Fe₂O₃94.72%min 50
  • Loss on ignition0.34%max 6.0
  • Moisture0.04%max 3.0
  • SO₃0.061%max 5.0
  • Passing 45 µm49.46%

As stated on the report, the sample was supplied by us and not drawn by SGS. It is an unclassified dry fly ash sample: at 49.46% passing 45 µm it sits outside the 34%-retained fineness limit, and it is not representative of the classified Grade I material covered by the NBML reports above, which measured 20.40–30.12% retained. This report is a chemistry cross-check only — it does not establish ASTM C618 Class F conformity, which also needs strength activity index and fineness on a classified sample.

First page of the NBML physical test report, number NBML-NN-0978-2026-01 Open PDF
NBML Building Materials Testing Lab IS 3812 P1 & P2

Fly ash — fineness, silo C10

Report no.
NBML-NN-0978-2026-01
Issued
13 Jul 2026
Source
C10
Method
IS 1727 Cl. 6.2 — wet sieving
  • Retained on 45 µm20.40%max 34
First page of the NBML physical test report, number NBML-NN-0978-2026-02 Open PDF
NBML Building Materials Testing Lab IS 3812 P1 & P2

Fly ash — fineness, silo C04

Report no.
NBML-NN-0978-2026-02
Issued
13 Jul 2026
Source
C04
Method
IS 1727 Cl. 6.2 — wet sieving
  • Retained on 45 µm21.00%max 34
Who tests it

Independent laboratories, not our own bench.

01

SGS India Pvt Ltd

Part of SGS SA — the world's largest inspection, verification and testing group. Chemistry run at their Ambattur, Chennai multi-laboratory against ASTM C311 methods, on a sample supplied by us. A cross-check on chemistry, not a Class F qualification.

02

NBML Building Materials Testing Lab LLP

A BIS-approved, Government of India certified laboratory at Raipur (ISO 9001:2015, 14001:2015 and 45001:2018). Physical and chemical testing to IS 3812 Parts 1 & 2 and IS 1727, with a QR-verifiable report.

Lot-tested before every dispatch Signed test certificate travels with the load QR verification on NBML reports Retained samples held by the lab
With your order

Paperwork that clears your QA desk.

01

Lot test certificate

A signed test certificate for the tested lot you receive — not a generic brochure figure — so your QA engineer can match the paperwork to the load.

02

Independent test reports on file

The reports on this page, supplied as originals with your quotation for tender and pre-qualification submissions.

03

Project-specific testing

Need a parameter this page doesn't cover — lime reactivity, 28-day strength, a particular grading? Say so with your enquiry and we'll have it tested.

Seen the numbers?

Get them priced for your plant.

Send your grade, monthly tonnage and delivery location — we come back within one business day with availability, packing and a landed price, test profile attached.

Get a quote